| Ceiling R-value | 38 |
| Wood Frame Wall R-value | 13 |
| Mass Wall R-value i | 5/10 |
| Floor R-value | 19 |
| Basement Wall R-value c | 10/13 |
| Slab R-value d, Depth | 10, 2 ft |
| Crawlspace Wall R-value c | 10/13 |
| Fenestration U-Factor b | 0.35 |
| Skylight U-Factor b | 0.60 |
| Glazed fenestration SHGC b, e | NR |
| Ceiling R-value | 38 |
| Wood Frame Wall R-value | 20 or 13+5h |
| Mass Wall R-value i | 13/17 |
| Floor R-value | 30g |
| Basement Wall R-value c | 10/13 |
| Slab R-value d, Depth | 10, 2 ft |
| Crawlspace Wall R-value c | 10/13 |
| Fenestration U-Factor b | 0.35 |
| Skylight U-Factor b | 0.60 |
| Glazed fenestration SHGC b, e | NR |
| Ceiling R-value | 49 |
| Wood Frame Wall R-value | 20 or 13+5h |
| Mass Wall R-value i | 15/19 |
| Floor R-value | 30g |
| Basement Wall R-value c | 15/19 |
| Slab R-value d, Depth | 10, 4 ft |
| Crawlspace Wall R-value c | 10/13 |
| Fenestration U-Factor b | 0.35 |
| Skylight U-Factor b | 0.60 |
| Glazed fenestration SHGC b, e | NR |
| Ceiling R-value | 49 |
| Wood Frame Wall R-value | 21 |
| Mass Wall R-value i | 19/21 |
| Floor R-value | 38g |
| Basement Wall R-value c | 15/19 |
| Slab R-value d, Depth | 10, 4 ft |
| Crawlspace Wall R-value c | 10/13 |
| Fenestration U-Factor b | 0.35 |
| Skylight U-Factor b | 0.60 |
| Glazed fenestration SHGC b, e | NR |